Tel: 136-0396-0595
Email: lyxcxcl@163.com
Address: Baiying Village, Xindian Town, High tech Zone, Luoyang City
Key process steps
Substrate preparation
Raw material: High purity tungsten plate (purity ≥ 99.95%) is used, with a common thickness of 0.1mm~50mm.
Pre processing: Obtain approximate dimensions through rolling or forging to eliminate internal stress.
Rough grinding
Equipment: Surface grinder (diamond grinding wheel) or double-sided grinder.
Parameters: Grinding wheel particle size # 80~# 200, removing surface oxide layer and macroscopic unevenness.
Fine grinding
Grinding wheel particle size: # 400~# 800, surface roughness Ra ≤ 0.4 μ m.
Coolant: Deionized water or specialized cutting fluid must be used to avoid contamination.
Polishing
Mechanical polishing: Diamond polishing paste (0.5~3 μ m particle size)+lint free polishing disc, Ra can reach 0.05 μ m.
Electrolytic polishing: suitable for ultra mirror surface requirements (Ra<0.01 μ m), requiring control of voltage and electrolyte formula (such as NaOH solution).
Cleaning and testing
Ultrasonic cleaning (acetone+alcohol) to remove residual abrasives.
Testing items:
Surface roughness (white light interferometer)
Flatness (laser planimeter, ± 0.005mm/m ²)
Microscopic defects (electron microscopy).
Technical difficulties and solutions
Question Reason Solution
Surface scratches Tungsten has high hardness and is embedded with abrasives Replace finer grinding wheels in stages and strengthen cleaning
Edge cracking Tungsten has high brittleness Chamfering pretreatment to reduce feed rate
Stain Polishing heat causes surface oxidation Inert gas protection polishing or subsequent acid washing (such as HF+HNO ∝)
Performance parameters (example)
Grade of smoothness:
Ordinary polishing: Ra 0.1~0.4 μ m (similar to stainless steel mirror panels)
High precision polishing: Ra ≤ 0.025 μ m (optical grade)
Tolerance control:
Thickness tolerance: ± 0.005mm (10mm thick plate)
Parallelism: ≤ 0.01mm/100mm
Main application scenarios
Semiconductor equipment
The electrostatic suction cup (ESC) substrate used for wafer processing requires ultra-high flatness to prevent wafer deformation.
Medical shielding
The tungsten aperture (multi leaf collimator) in radiotherapy equipment is affected by surface smoothness, which affects radiation scattering.
Vacuum coating
Evaporation boats or sputtering target liners must have defect free surfaces to ensure coating uniformity.
Research instruments
The flatness of the X-ray diffractometer sample stage affects the detection accuracy.